Determination of Statcom parameters for voltage control at 132 kv bus bar in Zanzibar Mtoni substation.

dc.contributor.authorShariff, Shariff Khator
dc.date.accessioned2020-07-29T10:58:49Z
dc.date.available2020-07-29T10:58:49Z
dc.date.issued2018
dc.descriptionAvailable in print form, East Africana Collection, Dr. Wilbert Chagula Library, Class mark (THS EAF TK2851.23 S352)en_US
dc.description.abstractThe voltage at the bus bar in Zanzibar Mtoni Substation sometimes reaches above the predetermined value of during light loading conditions. This caused a frequent tripping of the circuit breaker and thus interruption of power to consumers. The transmission line was represented with a nominal π model. The STATCOM dynamic range of was determined by considering the system fault level value at Tegeta Substation and a DC capacitor value of was evaluated. The STATCOM model applied three levels VSC that was synthesized with a Neutral Point Clamped configuration. Modified Park transformation matrix was applied in the VSC for the purpose of creating PWM pulse for switching the GTOs. MATLAB/Simulink R2010a version was used to simulate the proposed models of power network and STATCOM for the purpose of evaluating voltage at bus bar for different loading conditions. Simulation results revealed that, for the light load of before application STATCOM, the highest and lowest receiving end voltage were and respectively but after application STATCOM, the value were and respectively. In case of full load of before the application of STATCOM, the highest and lowest receiving end voltages were and respectively but after application of STATCOM, the values were and respectively. It could be concluded that, the STATCOM device had a capability of controlling the voltage to be within a tolerance of of the nominal system voltage at Zanzibar Mtoni Substation bus bar.en_US
dc.identifier.urihttp://41.86.178.5:8080/xmlui/handle/123456789/13285
dc.language.isoenen_US
dc.publisherUniversity of Dar es Salaamen_US
dc.subjectVoltage regulatoren_US
dc.subjectElectric controlleren_US
dc.subject132 kv Bus Baren_US
dc.subjectMtoni substationen_US
dc.subjectZanzibaren_US
dc.titleDetermination of Statcom parameters for voltage control at 132 kv bus bar in Zanzibar Mtoni substation.en_US
dc.typeThesisen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Shariff 2018.pdf
Size:
133.13 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: