Repository logo
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Log In
    New user? Click here to register. Have you forgotten your password?
Repository logo
    Communities & Collections
    All of DSpace
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Log In
    New user? Click here to register. Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Mhamilawa, Edward E"

Now showing 1 - 1 of 1
Results Per Page
Sort Options
  • Loading...
    Thumbnail Image
    Item
    A design of a temperature controller using a semiconductor diode as a transducer
    (University of Dar es Salaam, 1977) Mhamilawa, Edward E
    This project is an experimental attempt in designing a working instrument which utilizes the thermal priorities of a dioxide as a temperature meter and controller. The first chapters of the project report discuss into detail the physics of semiconductors and through mathematical analysis the temperature effect of the semiconductor is realized. In particular a semiconductor diode is found to exhibit quite a linear relationship between temperature and its voltage drop across the junction in the forward direction. Experimental results are contained to verify this and some graphs are plotted for both germanium and silicon dioxides. From these experimental results a suitable semiconductor diode is chosen. This diode is a germanium OA95 in glass casing. Any other germanium diode could do provided that the size, durability, availability, sensitivity and suitable operating current and voltage values of the diode as a temperature sensor are taken into considerations. After establishing a suitable temperature sensing device, a practical design on an instrument which can act as a temperature sensor is, stage by stage, fully discussed. The design starts with the building of transducer unit which holds the diodes. The procedure of measuring the temperature of a medium is first decided. It is chosen that there ought to have two diode of almost identical properties. The purpose of one is to be placed in a fixed reference temperature whereas the other diode is placed in a medium whose temperature is to be occupied with the reference temperature. Thus the temperature readings obtained, strictly speaking, are temperature differences between the two diode, and this is conveniently detected as voltage difference between the anodes of two sensing diodes. To simplify the design, especially for calitration, we have chosen only two reference temperature. One is the 0˚c reference temperature, allowing the diode sensor to act as a thermometer which can read in ˚C from 0 to 50 ˚C. The other reference is the room temperature, where room is taken to be any fixed temperature between 20 ˚C to 30 ˚C. This scaling allows a maximum temperature difference reading of about 25 ˚C only. Due to the properties of the sensor the permitted range of temperature operation is between 0 to 50 ˚C. a study of the behaviour in which the differential voltage varies with temperature revealed that for a given temperature change their corresponded a very small voltage difference in terms of Millivolts. Therefore, an operational simplifier was essential to boost up the voltage output. Temperature control of any medium is achieved by using a Schmitt trigger switching circuit which drives an electrochemical relay. This relay has terminals for connecting heating or cooling electric systems. Selection of temperature to be controlled between 0 ˚C and 50 ˚C is achieved by varying switching levels of the Schmitt trigger. A meter calibrated in degree is coupled at the input of the Schmitt trigger. In spite of the unsolved problems faced during the design the instrument has the ability of controlling temperature to be a mean fluctuation of 0.2 ˚C, but it depends on the power of the heating and cooling agents. Its accuracy in reading temperature is about ± 1 ˚C. The simplicity and low cost of the design as compared to the work it can possibly do warrants some future work on it, and if possible be adopted as a useful locally made instrument for laboratory use.

About Library

The University of Dar es Salaam Library is a vital source of scholarly information that facilitates users to get access to learning and research resources during their studies. It provides access to a wide range of resources in both print and digital formats and conducive reading environment for users, regardless of their physical conditions. All registered users are eligible to access library resources and can borrow print materials from general shelves for a specific period of time.

Useful Links

Koha Staff Login

University Research Repository

WebMail

Aris

Book Study Room

Mara Oral History

Hansard

SOCIAL MEDIA

Instagram

Facebook

Twitter

YouTube

WhatsApp

Ask Librarian

Contact Us

Postal Address
P.O.Box 35092
Dar es Salaam

Call Us: +255 22 2410500/9 Ext. 2165 ; Direct line +255 22 2410241

Fax No:: +255 22 2410241

Email:: directorlibrary@udsm.ac.tz

2025 University of Dar es Salaam - University Of Dar Es Salaam Library
Term of use / Privacy Policy