Repository logo
  • English
  • Català
  • ÄŒeÅ¡tina
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • LatvieÅ¡u
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Log In
    New user? Click here to register. Have you forgotten your password?
Repository logo
    Communities & Collections
    All of DSpace
  • English
  • Català
  • ÄŒeÅ¡tina
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • LatvieÅ¡u
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Log In
    New user? Click here to register. Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Masoud, Ali Othman"

Now showing 1 - 1 of 1
Results Per Page
Sort Options
  • Loading...
    Thumbnail Image
    Item
    Validation of optimization of patient dose and image quality for low cost computed radiography in selected hospitals in Tanzania
    (University of Dar es Salaam, 2015) Masoud, Ali Othman
    The study was conducted to assess the current status of patient dose and image quality by applied international code of practice for dosimetry in diagnostic radiology. Determination of the entrance surface air kerma (ESAK) to patients and image quality using image criteria rating (ICR) were made in five referral Hospitals in Tanzania. The average patient dose during computed radiography (CR) examination of the chest and abdomen values were 0.33 mGy and 3.70 mGy, respectively. The estimated uncertainty in patient dose values was approximately 24%. The effective dose for chest PA ranged from 0.02 mSv to 0.08 mSv while for abdomen AP, ranged from 0.19 mSv to 0.78 mSv. The image quality of radiographs of Phillips FCR Capsula CR-FR- 359 and Phillips PCR Eleva were found to be comparable. However, all facilities seemed to operate at higher tube load values, which can lead to unnecessary patient doses. Inadequate initial training on CR technology explains in large proportion of the inappropriate use of exposure parameters. The tube potential of 70 kVp and tube charge of 5 mAs were found to be optimal values, which can reduce the average patient dose up to s 55% if replaced 72 kVp and 20.8 mAs used routinely at KH.

About Library

The University of Dar es Salaam Library is a vital source of scholarly information that facilitates users to get access to learning and research resources during their studies. It provides access to a wide range of resources in both print and digital formats and conducive reading environment for users, regardless of their physical conditions. All registered users are eligible to access library resources and can borrow print materials from general shelves for a specific period of time.

Useful Links

Koha Staff Login

University Research Repository

WebMail

Aris

Book Study Room

Mara Oral History

Hansard

SOCIAL MEDIA

Instagram

Facebook

Twitter

YouTube

WhatsApp

Ask Librarian

Contact Us

Postal Address
P.O.Box 35092
Dar es Salaam

Call Us: +255 22 2410500/9 Ext. 2165 ; Direct line +255 22 2410241

Fax No:: +255 22 2410241

Email:: directorlibrary@udsm.ac.tz

2025 University of Dar es Salaam - University Of Dar Es Salaam Library
Term of use / Privacy Policy